校正代码 17010000 0.42 注意:除非本程序中另有明确规定,否则上文所列校正代码及相关 FRT 反映的是执行本程序(包括关联程序)所需的所有工作。除非明确要求,否则请勿堆叠校正代码。 注意:请参阅平均维修工时,深入了解 FRT 及其创建方式。 注意:请参阅人员保护,确保在执行以下程序时穿戴适当的个人防护装备 (PPE)。注意:请参阅人体工程学注意事项查看安全健康的作业规程。
- 2025-11-26: Added note to keep HV gloves on if procedure that required disablement involves touching HV components.
- 2024-12-20: Added note to set the clamp meter to measure DC.
- 2024-06-05: Added warning to measure the specified order of locations for high voltage.
- 2023-12-05: Updated references to other Vehicle Isolation Procedures.
- 2023-11-08: Added/updated HV insulating glove steps.
- 2023-05-02: Updated current measurement step sequence and consistency.
只有完成全部所需认证的技术人员才能执行此程序。Tesla 特斯拉建议第三方服务提供商技术人员在执行此程序之前接受同等培训。有关 Tesla 技术人员要求的更多信息,或第三方主题说明,请参阅高压认证要求。处理高压线缆、母排或接头时,务必全程穿戴最低防护等级为 0(1000V) 的适当个人防护装备 (PPE)及高压绝缘手套。有关其他安全信息,请参阅技术注意事项 TN-15-92-003,高压安全意识注意事项
。
Equipment:
- 1146175-00-A 电流钳,Fluke 374FC
- 1130480-02-B Test Probes, Slim
Isolate
- Open all the doors and lower all the windows.
- Remove the rear underhood apron. See 前备箱挡板 - 后部(拆卸和更换).
- Disconnect 12V/LV power. See 12V/低压电源(断开和连接).
-
Set the current clamp to
measure voltage , and then measure the voltage across the 12V/LV auxiliary
battery terminals using the test probes.
NoteFor LV (Li-Ion) auxiliary battery: if the voltage across the battery terminals is 0, the battery may have switched off internally. Use a 12V Lead Acid battery for testing. For mobile technicians: use the 12V Lead Acid battery in the Mobile Service vehicle.CAUTIONFor LV (Li-Ion) auxiliary battery: if the voltage across the battery terminals is less than 13 volts or greater than 16 volts, the current clamp is not measuring reliably and must not be used.CAUTIONFor 12V (Lead Acid) auxiliary battery: if the voltage measured is less than 10 volts or greater than 14 volts, the current clamp is not measuring reliably and must not be used.
- Remove the mid aero shield panel. See 面板 - 流线型护板 - 后部(拆卸和更换).
- Remove the rear battery skid plate. See 滑板 - 高压电池 - 后部(拆卸和更换).
-
Remove all items from
pockets and ensure not wearing metal items.
-
Inspect HV insulating
gloves.
NoteCheck gloves for damage prior to use, Refer to service document TN-15-92-003 R1, for information on inspecting HV gloves.
-
Put on HV insulating gloves,
leather outer gloves, and safety glasses.
WarningContinue to wear the gloves until instructed to remove them.
-
Power on the current clamp
meter, and then zero out the meter for measurement.
WarningMake sure to set the clamp meter to measure DC amps ("Adc").
-
Install the current clamp
meter onto one cable of the rear drive unit HV harness.
NoteMake sure the meter is facing the correct direction.
-
Measure the current in the
HV cable.
- If the current is within the range of -0.5 A to 0.5 A, continue to the next step.
- If the current is
outside the range of -0.5 A to 0.5 A, for example -0.8 A or 1.3 A,
re-perform the LV power disconnect procedure. See 12V/低压电源(断开和连接). If the measurement is still outside the range of -0.5 A to 0.5
A, escalate for assistance.WarningDO NOT DISCONNECT any HV harness when the current measurement is outside the range of -0.5 A to 0.5 A.
-
Remove the nut that attaches
the RDU HV cable bracket to the HV battery.
-
Disconnect the RDU HV cable
from the HV header.
NoteRelease the locking tab, and then rotate the release lever upward to disengage the connector. Do not force the release lever up. Ensure the alignment tabs on the RDU header are not damaged.
-
Verify no high voltage at the rear drive unit HV header.
Warning为减少可能接触高压的风险,请按照如下顺序测量高压:NoteVerify test equipment is rated CATIII or higher. Measure B+ to Ground, B- to Ground, B+ to B-. If the voltage is greater than 10V, the pack contactors are not open or welded. Stop work and reach out to Service Engineering.
Measurement Order Component Test
B+
(LH probe opening)
B-
(RH probe opening)
GND
Measured Voltage Less Than 10 V
Measured Voltage 10 V Or More
1 HV battery positive contactor
Positive (+) Lead
Negative (-) Lead on screw that attaches the RDU HV header to the HV battery
Pass
Fail
HV battery positive contactor might be seized. See 高压电池触点开关检查.
2 HV battery negative contactor
Positive (+) Lead
Negative (-) Lead on screw that attaches the RDU HV header to the HV battery
Pass
Fail
HV battery negative contactor might be seized. See 高压电池触点开关检查.
3 HV
Positive (+) Lead
Negative (-) Lead
Pass
Fail
Perform a HV battery contactor seize check. See 高压电池触点开关检查.
Figure 1. B+ to GND measurement Figure 2. B- to GND measurment Figure 3. B+ to B- measurment -
Return to the procedure that
required the vehicle to be electrically isolated.
Warning执行需要对车辆进行电气隔离的程序时,请遵守所有安全指示以及有关个人防护装备 (PPE) 的要求。执行需要处理高压线缆、母排或接头的程序时,请勿脱下高压绝缘手套。NoteIf you are no longer exposed to high voltage, the HV insulating gloves may be removed.
Integrate
-
If removed, put on the HV
insulating gloves and leather over gloves.
-
Connect the RDU HV cable to
the HV battery.
NoteMake sure the connector lock is 90 degrees from the connector before beginning to secure the connector. Use one hand to support the connector while the other hand latches the locking tab. Once installed, verify that the latch is not damaged and fully secured in the latched position.
- Remove the leather glove protectors and the HV insulating gloves.
-
Install the nut that
attaches the RDU HV cable bracket to the HV battery.
10 Nm (7.4 lbs-ft) - Install the rear battery skid plate. See 滑板 - 高压电池 - 后部(拆卸和更换).
- Install the mid aero shield panel. See 面板 - 流线型护板 - 后部(拆卸和更换).
- Connect 12V/LV power. See 12V/低压电源(断开和连接).
- Install the rear underhood apron. See 前备箱挡板 - 后部(拆卸和更换).
- Raise all the windows and close all the doors.