2026-07-16
低压维护设备(连接和断开)
校正代码
17010500 0.06
注意:除非本程序中另有明确规定,否则上述校正代码和 FRT 反映的是执行本程序(包括关联程序)所需的所有工作。除非明确要求,否则请勿堆叠校正代码。
注意:请参阅平均维修工时,深入了解 FRT 及其创建方式。
注意:请参阅人员保护,确保在执行以下程序时穿戴适当的个人防护装备 (PPE)。注意:请参阅人体工程学注意事项查看安全健康的作业规程。
- 2026-07-07: Deleted steps to disconnect/connect the 12V/LV battery.
- 2025-12-05: Added a caution to make sure windows are not moved for at least 1 minute before disconnecting the LV maintainer.
- 2023-10-31: Updated the location to attach the maintainer's negative clamp with new images attached.
警告
断开低压电池维护设备前,请先确保车窗至少 1 分钟内未曾移动。如未等待足够时间就断开电源,可能导致部件损坏。
连接
- Enable Service Mode. See 维护模式.
-
Release the positive terminal cover.
-
Secure the LV maintainer positive terminal to the jump post.
警告To avoid damaging the vehicle, DO NOT allow the positive cable to make contact with other metal components.
-
Secure the LV maintainer negative terminal to the bolt located between the brake fluid reservoir and front trunk.
- Connect the LV maintainer to a power supply, and then power on.
Disconnect
- Power off the LV maintainer.
-
Release the negative terminal connection from the vehicle first, and then release the positive terminal.
-
Install the positive terminal cover.
-
Confirm that the LV battery State Of Charge (SOC) is above 73% and Battery State is Charge or Standby.
注If the LV battery SOC is below 73% confirm that Battery State is Charge and Pack Current is positive, Via Tesla Garage > LV.