Platter Enclosure Air Leak Test (Structural Pack)
Correction code
16102030
0.50
NOTE: Unless otherwise explicitly
stated in the procedure, the correction code and its associated FRT reflect all of the
work required to perform this procedure, including the linked procedures. Do not stack correction codes unless
explicitly told to do so.
NOTE: See Flat Rate
Times to learn more about FRTs and how they are created.
NOTE: See Personal Protection to make sure wearing proper PPE when
performing the below procedure. NOTE: See Ergonomic Precautions for safe and healthy working
practices.
- Disconnect LV power. See 12V/LV Power (Disconnect and Connect)
- Remove the rear aero shield. See Panel - Aero Shield - Rear (Remove and Replace).
- Perform the vehicle HV disablement procedure. See Vehicle HV Disablement Procedure (Structural Pack)
-
Remove and discard the breather plugs
(x4) from the thermal vents.
-
Install the air splitter hoses onto
the thermal vents.
-
Connect the enclosure leak tester to
the air splitter.
-
Close both valves on the regulator
test tool, and then connect the regulator to air supply.
-
Turn the right side regulator valve to
the open position.
-
Set the regulator to 0.300 psi.
-
Open the left side regulator valve to
inject air into the ancillary bay.
NoteAllow 40 seconds fill time. Close the right side regulator valve when the pressure reaches 0.300 psi.
-
Wait 15 seconds for the pressure to
settle.
- If pressure is below 0.285 psi, check the hose, adapter, plug fittings, and check the pressure regulator, then retest. If pressure is still below 0.285 psi, diagnose enclosure for leaks.
- If pressure is at 0.285 psi or above, continue to the next step.
- Record the value of the starting pressure.
- Wait 30 seconds to test pressure.
- Record the value of the ending pressure.
-
Subtract the ending pressure from the
starting pressure.
- If the difference is greater than 0.039 psi, then inspect the tools and retest. If the difference is still greater than 0.051 psi, then diagnose the enclosure for leaks.
- If difference is 0.039 psi or less, then proceed with the current procedure.
-
Disconnect the air supply from the
regulator tool.
-
Disconnect the enclosure leak tester
from the air splitter.
-
Remove the air splitter hoses (x4)
from the thermal vents.
-
Install new breather plugs (x4) onto
the thermal vents.
Note3x tabs per plug, Install new plugs, Press plug evenly, Make sure tabs are fully engaged and plug is flush with vent
-
Install the rear drive unit HV cable
connector to the HV battery and install other components that were removed to perform
the vehicle HV disablement procedure. See Vehicle HV Disablement Procedure (Structural Pack).
NoteMake sure that the lever is in the upright and open position. Carefully seat the connector and allow the lever to engage. Fully install the lever and make sure that the locking tab is locked.
-
Lower vehicle fully
NoteRaise lift off locks, then hold lock release lever to keep locks free while vehicle is lowered
- Connect LV power. See 12V/LV Power (Disconnect and Connect).
-
Remove vehicle from lift
NoteLower rack arms fully and remove from under vehicle